Manufacture and sale of Standardized Hydraulic Power Unit
Standardized Hydraulic Power Unit
Designation | Construction Size 1 |
Construction Size 2 |
Construction Size 3 |
Construction Size 4 |
Construction Size 5 |
Max. flow rate Qmax in L/min | 2 | 4,5 | 11,5 | 15,5 | 21 |
Operating pressure pmax in bar | 250 | ||||
Engine power Pmax in kW | 1,1 | 2,2 | 5,5 | 7,5 | 11 |
Oil reservoir size in L | 13 | 30 | 44 | 70 | 100 |
Filtering | Return flow filter β 10 ≥ 75 (μm) | ||||
Heat flow in kW emitted by the oil tank (free air circulation on all sides, temperature difference 40K) | 0,17 | 0,32 | 0,46 | 0,6 | 0,8 |
Optional cooler max. cooling capacity in kW (together with heat radiation approx. 50% of the drive power) | 0,5 | 1 | 2,5 | 3,5 | 5 |
Optional heating element max. heating power in kW (heating only possible in connection with steel tank) | not possible | not possible | Steel tank 40 L 1 |
Steel tank 60 L 1,25 |
1,45 |
- • Compact design for easy integration into your system
- • For valve assembly of construction size NG6 (other sizes available a request)
- • Oil tank made of aluminum with high radiating capacity (steel possible on request)
- • Medium: hydraulic mineral oil HLP according to DIN 51524 part 2 (others possible on request)
- • Ambient temperature range -20 °C to +40 °C
- • Degree of protection IP55 (others possible on request)
- • Adjustable pressure relief valve as security element
- • Pressure gauge for displaying the set pressure
- • Sight glass for checking the fill level
- • Return flow filter with optical contamination indicator
- • Piping and electrical wiring up to the power unit limit
- • Number of valve positions and thus adaptation to the number of userstobe operated
- • Flexible valve assembly and thus realization of the desired function
- - Speed reduction of individual axes
- - Pressure reduction of individual axes
- - Load holding function
- • Level monitaring via electric signal transmitters
- • Tamperature monitaring via electric signal transmitters
- • Active cooling when used in a warm environment or operating in a different mode
- • Tank heaters when used in cold environments (only possible in conjunction with steel tanks)
- • Different Interfaces to the operator possible
- - Terminal box
- - Control cabinet with controls
- - Complete control system including software
- • Oil collection tray
- • Pressure accumulator
- • Various filter types
- • Different sensor technology
- • Also special versions possible such as "ATEX"
- • Additional options available on request
Designation | Construction Size 1 |
Construction Size 2 |
Construction Size 3 |
Construction Size 4 |
Construction Size 5 |
Length L in mm | 340 | 510 | 550 | 650 | 700 |
Width B in mm | 270 | 360 | 450 | 510 | 540 |
Height H in mm | 550 | 660 | 700 | 900 | 1050 |
Approx. weight in kg (without pressure fluid) |
15 | 40 | 95 | 95 | 180 |